Compartilhamento |
|
Use este identificador para citar ou linkar para este item:
http://bdtd.famerp.br/handle/tede/755
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Arcanjo, Ana Beatriz Braga | - |
dc.creator.Lattes | http://lattes.cnpq.br/5409944541384910 | por |
dc.contributor.advisor1 | Beccaria, Lúcia Marinilza | - |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/9454722257798034 | por |
dc.contributor.referee1 | Castro, Meire Cristina Novelli e | - |
dc.contributor.referee1Lattes | http://lattes.cnpq.br/3077352830877950 | por |
dc.contributor.referee2 | Cavenagui, Simone | - |
dc.contributor.referee3 | Frota, Oleci Pereira | - |
dc.contributor.referee3Lattes | http://lattes.cnpq.br/7615405125535218 | por |
dc.date.accessioned | 2022-11-09T16:26:09Z | - |
dc.date.issued | 2022-03-23 | - |
dc.identifier.citation | Arcanjo, Ana Beatriz Braga. Fatores associados à falha de extubação orotraqueal de pacientes na unidade de terapia intensiva. 2022. 97 f. Dissertação (Programa de Pós-Graduação em Enfermagem) - Faculdade de Medicina de São José do Rio Preto, São José do Rio Preto. | por |
dc.identifier.doi | 1643 | por |
dc.identifier.uri | http://bdtd.famerp.br/handle/tede/755 | - |
dc.description.resumo | Investigar os múltiplos fatores clínicos já recomendados pela literatura, como controle hemogasométrico, tempo de VMI, balanço hídrico, nível de criticidade, eficácia de tosse e presença de secreção pulmonar, que estariam mais fortemente associados à falha de extubação. Método: Estudo de caso-controle não pareado, longitudinal, retrospectivo, com abordagem quantitativa, realizado em um hospital de ensino, de porte especial do noroeste paulista. De 1703 pacientes sob ventilação mecânica invasiva, a amostra foi de 480, de ambos os sexos, em ventilação por mais de 24 horas, extubados de forma planejada, respeitando o protocolo institucional baseado nas Diretrizes Brasileiras de Ventilação Mecânica, entre janeiro de 2019 a dezembro de 2020. A coleta de dados foi por análise de prontuário eletrônico de parâmetros clínicos específicos para o desmame ventilatório e extubação: pressão parcial de oxigênio, pressão parcial de gás carbônico, hemoglobina, dias de ventilação mecânica anteriores à extubação, balanço hídrico, Acute Physiology and Chronic Health Evaluation II (APACHE II), Sequential organ failure assessment score (SOFA), quantidade de secreção pulmonar e efetividade da tosse. Foi realizada análise estatística comparativa (Teste de Fisher e Mann-Whitney) e regressão logística por meio do programa StatsDirect 3.3.5. Resultados: De 480 pacientes, 415 (86,5%) tiveram sucesso 48 horas após a extubação e 65 (13,5%) falharam, corroborando com taxa encontrada na literatura mundial. Do grupo controle, que tiveram sucesso, a média de idade foi de 55,1 (±17,1) e o resultado das variáveis foram: tempo de intubação orotraqueal antes do procedimento de extubação de quatro dias (2-5), PaO2 de 110,1 (91- 137), PaCO2 de 37,4 (32,5-42), hemoglobina de 10 (±2,1) g/dL, balanço hídrico positivo de 397 (-653-1654,5) ml, APACHE II em 20 (14-25) pontos, tosse fraca em 58 (13,9%). Do grupo de estudo, que foram reintubados, a média de idade foi 55,9 anos (±17,7) e o resultado das variáveis foram: dias de intubação orotraqueal antes do procedimento de 5 (3-5), PaO2 de 101,4(79-127), PaCO2 39,2 (34-46), hemoglobina de 9,7(±1,7)g/dL, balanço hídrico positivo de 1150 (144-3025) ml, APACHE II em 23 (19-29) pontos , tosse fraca em 31 (47,7 %) com presença de secreção pulmonar abundante em 47,7 %. A análise de regressão logística indicou as seguintes associações com a necessidade de reintubação: balanço hídrico positivo (OR, 1000169; IC95% 1,000061 a 1,000277) e tosse ineficaz (OR, 6588996; IC95% 3,566588 a 12,172661). Conclusões: Dos fatores associados à maior taxa de falhas na extubação orotraqueal, foram significantes o balanço hídrico positivo e a presença de tosse ineficiente ou incapacidade de higienizar a via aérea, sugerindo que esses fatores devem ser avaliados no processo de desmame e levados em consideração pela equipe multiprofissional para a tomada de decisão sobre extubar o paciente crítico na UTI. Além disso, o período de intubação orotraqueal superior a cinco dias, APACHE II com escore superior a 23 e a quantidade abundante de secreção brônquica devem ser considerados. A implicação para a prática clínica foi confirmar a importância da utilização do protocolo de extubação segura e apontar os parâmetros que servem de preditores para falhas, propiciando maior segurança ao paciente na UTI. | por |
dc.description.abstract | To investigate the multiple clinical factors already recommended by the literature, such as hemogasometric control, length of IMV, hydric balance, criticality level, coughing efficacy, and presence of pulmonary secretion, which would be more highly associated with extubation failure. Method: An unpaired, longitudinal, retrospective, casecontrol study with a quantitative approach, carried out in a special school hospital in the northwest of São Paulo. From a population of 1703 patients undergoing invasive mechanical ventilation, the sample comprised 480 patients, aged over 18 years, both sexes, on ventilation for more than 24 hours, who were extubated in a planned manner, according to the institutional protocol. based on the Brazilian Mechanical Ventilation Guidelines, over a period of two years (January 2019 to December 2020). Data collection was performed by analyzing electronic medical records of specific clinical parameters for the extubation process: partial pressure of oxygen, partial pressure of carbon dioxide, hemoglobin, days of mechanical ventilation prior to extubation, water balance, Acute Physiology and Chronic Health Evaluation II (APACHE II), Sequential organ failure assessment score (SOFA score), amount of pulmonary secretion and coughing effectiveness. Comparative analysis and multiple regression were performed using the statistical program StatsDirect 3.3.5. Results: Of the 480 patients, 415 (86.5%) were successful 48 hours after extubation, and 65 (13.5%) failed, in agreement with the rate found in the world literature. Of the control group, those who were successful, the mean age was 55.1 (±17.1) and the result of the variables were: days of orotracheal intubation before the extubation procedure of 4 (2-5), PaO2 of 110 .1 (91-137), PaCO2 of 37.4 (32.5- 42), hemoglobin of 10 (±2.1) g/dL, positive fluid balance of 397 (-653-1654.5) ml, APACHE II in 20 (14-25) points, weak coughing in 58 (13.9%). Of the studied group, who were reintubated, the mean age was 55.9 (±17.7), and the outcome variables were: days of orotracheal intubation before the extubation procedure of 5 (3-5) , PaO2 of 101.4(79-127), PaCO2 39.2 (34-46), hemoglobin of 9.7(±1.7)g/dL, positive fluid balance of 1150 (144- 3025) ml, APACHE II in 23 (19-29) points, weak coughing in 31 (47.7%) with abundant pulmonary secretions in 47.7%. Logistic regression analysis indicated the following associations with the need for reintubation: positive fluid balance (OR, 1000169; 95%CI 1.000061 to 1.000277) and ineffective coughing (OR, 6588996; 95%CI 3.566588 to 12.172661). Conclusions: Among the factors associated with the higher rate of orotracheal extubation failures; positive fluid balance and the presence of inefficient coughing or inability to hygienize the airway were significant, suggesting that these factors should be assessed in the weaning process and taken into account by the multiprofessional team when making a decision on extubating the critically ill patient in the ICU. Furthermore, orotracheal intubation period longer than five days, APACHE II score higher than 23 and abundant bronchial secretion should be considered. The implication for clinical practice was to support the importance of using the safe extubation protocol and to point out the parameters that could be predictors of failures, providing greater safety to the patient in the ICU. | eng |
dc.description.provenance | Submitted by Suzana Dias ([email protected]) on 2022-11-09T16:26:09Z No. of bitstreams: 1 AnaBeatrizBragaArcanjo_Dissert.pdf: 1088712 bytes, checksum: 81689039675a9298130691bc53dd3293 (MD5) | eng |
dc.description.provenance | Made available in DSpace on 2022-11-09T16:26:09Z (GMT). No. of bitstreams: 1 AnaBeatrizBragaArcanjo_Dissert.pdf: 1088712 bytes, checksum: 81689039675a9298130691bc53dd3293 (MD5) Previous issue date: 2022-03-23 | eng |
dc.format | application/pdf | * |
dc.language | por | por |
dc.publisher | Faculdade de Medicina de São José do Rio Preto | por |
dc.publisher.department | Faculdade 1::Departamento 2 | por |
dc.publisher.country | Brasil | por |
dc.publisher.initials | FAMERP | por |
dc.publisher.program | Programa de Pós-Graduação em Enfermagem | por |
dc.rights | Acesso Aberto | por |
dc.subject | Extubação | por |
dc.subject | Airway Extubation | eng |
dc.subject | Unidades de Terapia Intensiva | por |
dc.subject | Intensive Care Units | eng |
dc.subject | Manuseio das Vias Aéreas | por |
dc.subject | Airway Management | eng |
dc.subject.cnpq | CIENCIAS DA SAUDE | por |
dc.title | Fatores associados à falha de extubação orotraqueal de pacientes na unidade de terapia intensiva | por |
dc.type | Dissertação | por |
Aparece nas coleções: | Programa de Pós-Graduação em Enfermagem |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
AnaBeatrizBragaArcanjo_Dissert.pdf | Documento principal | 1,06 MB | Adobe PDF | Baixar/Abrir Pré-Visualizar |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.