Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bdtd.famerp.br/handle/tede/239
Registro completo de metadados
Campo DCValorIdioma
dc.creatorGandolfi, José Franciscopt_BR
dc.creator.Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4779377J0por
dc.contributor.advisor1Braile, Domingo Marcolinopt_BR
dc.contributor.advisor1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4767966J3&dataRevisao=nullpor
dc.contributor.referee1Moscardini, Airton Camachopt_BR
dc.contributor.referee1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4731967J8&dataRevisao=nullpor
dc.contributor.referee2Tognola, Waldir Antoniopt_BR
dc.contributor.referee2Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4775349Z7&dataRevisao=nullpor
dc.contributor.referee3Souza, Dulcimar Donizete dept_BR
dc.contributor.referee3Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4779372Z3por
dc.date.accessioned2016-01-26T12:51:54Z-
dc.date.available2007-04-20pt_BR
dc.date.issued2006-03-06pt_BR
dc.identifier.citationGANDOLFI, José Francisco. Avaliação in vitro e ex vivo de oxigenador de membrana de baixa resistência para o uso ECMO sem auxílio de bomba. 2006. 131 f. Tese (Doutorado em Medicina Interna; Medicina e Ciências Correlatas) - Faculdade de Medicina de São José do Rio Preto, São José do Rio Preto, 2006.por
dc.identifier.urihttp://bdtd.famerp.br/handle/tede/239-
dc.description.resumoA assistência pulmonar extracorpórea tem sido proposta como uma alternativa invasiva ao tratamento convencional, quando a oxigenação adequada torna-se impossível pelo uso de ventilação mecânica. A oxigenação extracorpórea por membrana (ECMO) realizada com auxílio circulatório pode produzir hemólise, distúrbios da coagulação, resposta inflamatória e complicações inerentes a um procedimento de alto risco e elevado custo. O objetivo deste trabalho foi avaliar a eficácia in vitro e ex vivo de um oxigenador de baixa resistência em ECMO sem auxílio circulatório. Material e Método: Inicialmente foram desenvolvidos diferentes protótipos do oxigenador de membrana de baixa resistência para testar a influência das condições de entrada e saída do sangue, área, quantidade e disposição das fibras no processo de oxigenação e remoção de gás carbônico (CO2). Nos testes in vitro, utilizando-se sangue bovino, foram avaliados fluxo médio, volume de sangue necessário para preencher o oxigenador ou priming, saturação de oxigênio e transferência de gás carbônico e o gradiente de pressão. Nos experimentos ex vivo foram utilizados cinco carneiros da raça Santa Inês, pesando entre 5 a 33 Kg. Em cada animal foram estudadas as variações com relação à saturação de O2, PO2 e PCO2, no sangue sistêmico, na saída do oxigenador e no sangue venoso com fluxos de oxigênio no oxigenador 0,5 L/min, 1,0 e 1,5 L/min. Resultados: O oxigenador demonstrou excelente desempenho mecânico, o que pode ser verificado pelos valores de PO2, PCO2 e SatO2 do sangue na saída do oxigenador. Do ponto de vista clínico, a melhora de PO2 e SO2 e a redução de PCO2 no sangue arterial sistêmico (artéria femoral do carneiro) foram evidentes nos cinco experimentos. Foi possível observar uma tendência para melhores resultados com pesos inferiores a 10,0 kg. Traduzindo-se essas relações em termos de fluxo sanguíneo e volemia total, os melhores resultados apareceram com proporção fluxo sangüíneo no oxigenador/volemia, de 20% ou maior, podendo-se estabelecer esse limite de corte, como fluxo ideal necessário para bom desempenho do oxigenador. Conclusão: Os testes de performance in vitro e desempenho ex vivo, realizados com o oxigenador de membrana de baixa resistência ao fluxo, para uso em circulação extracopórea arteriovenosa, sem o auxílio de bomba propulsora, mostraram resultados suficientes para concluir que tais dispositivos são capazes de fornecer Oxigênio e retirar gás Carbônico do sangue em quantidades suficientes para manter tais parâmetros em níveis aceitáveis, quando a ventilação está prejudicada.por
dc.description.abstractExtracorporeal pulmonary assistance has been proposed as an invasive alternative to the conventional treatment when adequate oxygenation becomes impossible by mechanical ventilation. Extracorporeal membrane oxygenation (ECMO) attained using assisted circulation may cause hemolysis, coagulation disorders, an inflammatory response and complications inherent to a high-risk high-cost procedure. The objective of this work was to evaluate the efficacy, both in vitro and ex vivo, of a low-resistance oxygenator in ECMO without assisted circulation. Material and Method: Initially, different prototypes of the low-resistance membrane oxygenator were developed to test the influence of the of inlet and outlet conditions of the blood, the area, the quantity and placement of the fibers in the oxygenation process and the removal of carbon dioxide gas (CO2). In the in vitro tests when bovine blood was utilized, the mean flow, volume of blood needed to fill the oxygenator and for priming, oxygen saturation, carbon dioxide gas exchange and the pressure gradient were measured. For the ex vivo experiments, five Santa Inês sheep, weighing between 5 and 33 kg, were used. In each animal, variations in respect to the oxygen saturation, the PO2 and the PCO2 were studied in the systemic blood at the outlet of the oxygenator and of the venous blood using oxygen flow rates of 0.5L/min, 1.0 L/min and 1.5 L/min. Results: The oxygenator had an excellent mechanical performance, which was seen by the PO2, PCO2 and oxygen saturation of the blood at the outlet of the oxygenator. From the clinical point of view, the improvement in the PO2 and oxygen saturation and the reduction in PCO2 of the systemic arterial blood (femoral artery of the sheep), were evident in the five sheep. A tendency of better results was seen when the weight was less than 10kg. Translating these relationships in terms of blood flow and total volume, the best results appeared when the blood flow in the oxygenator/volume proportion was 20% or greater, establishing this cutoff point as the ideal flow necessary for the best performance of the oxygenator. Conclusion: The in vitro and ex vivo performance tests achieved with the low-resistance membrane oxygenator used in arteriovenous extracorporeal circulation without the assistance of a propulsion pump, proved that this device is capable of providing oxygen and removing carbon dioxide from the blood in sufficient quantities to maintain the tested parameters at acceptable limits when ventilation is prejudiced.eng
dc.description.provenanceMade available in DSpace on 2016-01-26T12:51:54Z (GMT). No. of bitstreams: 1 josefranciscogandolfi_tese.pdf: 946147 bytes, checksum: 007d161afcdde952537f95c14f87bb0c (MD5) Previous issue date: 2006-03-06eng
dc.formatapplication/pdfpor
dc.languageporpor
dc.publisherFaculdade de Medicina de São José do Rio Pretopor
dc.publisher.departmentMedicina Interna; Medicina e Ciências Correlatas::123123123123::600por
dc.publisher.countryBRpor
dc.publisher.initialsFAMERPpor
dc.publisher.programPrograma de Pós-Graduação em Ciências da Saúde::6954410853678806574::600por
dc.rightsAcesso Abertopor
dc.subjectMembrane Oxygenatorspt_BR
dc.subjectExtracorporeal Membrane Oxygenationeng
dc.subjectOxigenador de Membrana de Baixa Resistênciapor
dc.subjectECMO sem Auxílio Circulatóriopor
dc.subjectEstudo Experimentalpor
dc.subjectCirculação Extracórporea com Oxigenador de Membranapor
dc.subjectOxigenación de la Membrana Extracorporeaspa
dc.subject.cnpqCNPQ::CIENCIAS DA SAUDE::MEDICINA::CLINICA MEDICA::PNEUMOLOGIA::123123123123::600por
dc.titleAvaliação in vitro e ex vivo de oxigenador de membrana de baixa resistência para o uso ECMO sem auxílio de bombapor
dc.typeTesepor