Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bdtd.famerp.br/handle/tede/186
Registro completo de metadados
Campo DCValorIdioma
dc.creatorMarchi, Carlos Henrique dept_BR
dc.creator.Latteshttp://lattes.cnpq.br/1253702783469544por
dc.contributor.advisor1Godoy, Moacir Fernandes dept_BR
dc.contributor.advisor1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4787885D5&dataRevisao=nullpor
dc.contributor.referee1Moscardini, Airton Camachopt_BR
dc.contributor.referee1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4731967J8&dataRevisao=nullpor
dc.contributor.referee2Crotti, Ulisses Alexandrept_BR
dc.contributor.referee3Santana, Maria Virgínia Tavarespt_BR
dc.contributor.referee3Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4793411E7&dataRevisao=nullpor
dc.date.accessioned2016-01-26T12:51:45Z-
dc.date.available2006-08-02pt_BR
dc.date.issued2004-09-10pt_BR
dc.identifier.citationMARCHI, Carlos Henrique de. Monitoração ecocardiográfica da atriosseptostomia com balão. 2004. 63 f. Tese (Doutorado em Medicina Interna; Medicina e Ciências Correlatas) - Faculdade de Medicina de São José do Rio Preto, São José do Rio Preto, 2004.por
dc.identifier.urihttp://bdtd.famerp.br/handle/tede/186-
dc.description.resumoAtnosseptostomia com balão (ASB) é procedimento de grande valor no tratamento de cardiopatias congênitas e monitorado tradicionalmente por radioscopia. O objetivo do presente estudo foi avaliar a ASB monitorada pela ecocardiografia. Casuística e Método: Entre agosto de 1997 e janeiro de 2004, 31 crianças foram submetidas à ASB sob monitoração ecocardiográfica exclusiva. Admitiu-se sucesso a obtenção de comunicação interatrial (CIA) com diâmetro igual ou maior que quatro milímetros (mm) e com ampla mobilidade das suas margens. Dados coletados: diâmetro da CIA e saturação arterial de oxigênio (SAT) iniciais e finais e número de trações do cateter balão. Resultados: Sexo masculino predominou (83,9%). A idade mediana foi de 5 dias (1-150) e o peso teve mediana de 3300g (1800-7500). Transposição das Grandes Artérias ocorreu em 80,6%, Atresia Tricúspide em 12,9%, Drenagem Anômala Total de Veias Pulmonares em 3,2% e Atresia Pulmonar com septo Integro em 3,2%. Sucesso foi obtido em todos os casos. O tamanho da CIA aumentou de 1,8 0,8 mm para 5,8 1,3 mm (p <0,0001) e a SAT aumentou de 64,5 18,9 % para 85,1 9,2 % (p < 0,0001). Complicações ocorridas: três rupturas de balão, uma lesão de veia femoral direita, uma taquicardia supraventricular e um flutter atnal. Conclusões: ASB monitorada pela ecocardiografia é método seguro e eficaz. Possibilita a realização do procedimento à beira do leito evitando o transporte da criança, identifica o posicionamento do cateter reduzindo complicações graves e avalia o resultado imediato do procedimento.por
dc.description.abstractObjective: Balloon atrial septostomy (BAS) is a life-saving palliative procedure for some congenital heart defects and typically performed in the cardiac catheterization laboratory. The aim of this study was to evaluate BAS under echocardiographic guidance. Method: From August 1997 through January 2004, 31 children with congenital heart defects with indication of ASB were submitted to the procedure under exclusive echocardiographic guidance. Success was admitted the obtaining of atrial septal defect (ASD) with size of four millimeters (mm) or greater and torn septal tissue flapping freely. Results: Male infants predominated (83.9%). Median age was 5 days (1 - 150) and median weight was 3300g (1800 - 7500). Transposition of the Great Arteries was present in 80.6%, Tricuspid Atresia in 12.9%, Total Anomalous Pulmonary Venous Return in 3.2% and Pulmonary Atresia with intact ventricular septum in 3.2%. The procedure was successful in all cases. ASD size increased from 1.8 ± 0.8 mm to 5.8 ± 1.3 mm (P<0.0001) and arterial oxygen saturation increased from 64.5 ± 18.9% to 85.1 ± 9.2% (P<0.0001). As complications occured three balloon ruptures, one tear of right femoral vein, one case of supraventricular tachycardia and one case of atrial flutter. Conclusion: BAS under echocardiographic guidance is a safe and effective method. It can be performed at the bedside, identifies the catheter location avoiding serious complications and evaluates the immediate result of the procedure.eng
dc.description.provenanceMade available in DSpace on 2016-01-26T12:51:45Z (GMT). No. of bitstreams: 1 carlosdemarchi_tese.pdf: 849020 bytes, checksum: f72fc171abbb042bef869d955b6fd632 (MD5) Previous issue date: 2004-09-10eng
dc.formatapplication/pdfpor
dc.languageporpor
dc.publisherFaculdade de Medicina de São José do Rio Pretopor
dc.publisher.departmentMedicina Interna; Medicina e Ciências Correlataspor
dc.publisher.countryBRpor
dc.publisher.initialsFAMERPpor
dc.publisher.programPrograma de Pós-Graduação em Ciências da Saúdepor
dc.rightsAcesso Abertopor
dc.subjectCardiopatia Congênitapor
dc.subjectEcocardiografiapor
dc.subjectAtriosseptostomia com Balãopor
dc.subjectCongenital Heart Defectseng
dc.subjectEchocardiographyeng
dc.subjectBalloon Atrial Septostomyeng
dc.subjectDilatação com Balãopor
dc.subjectBalloon Dilatationeng
dc.subjectDefeitos do Septo Interatrialpor
dc.subjectAtrial Heart Septal Defectseng
dc.subjectSepto Cardíacopor
dc.subjectHeart Septumeng
dc.subjectDilatación con Balonspa
dc.subjectDefectos del Septum Interatrialspa
dc.subjectSeptum Cardíacospa
dc.subject.cnpqCNPQ::CIENCIAS DA SAUDE::MEDICINA::CLINICA MEDICA::CARDIOLOGIApor
dc.titleMonitoração ecocardiográfica da atriosseptostomia com balãopor
dc.typeTesepor
Aparece nas coleções:Programa de Pós-Graduação em Ciências da Saúde

Arquivos associados a este item:
Arquivo TamanhoFormato 
carlosdemarchi_tese.pdf829,12 kBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.